Product Details
- High-speed biomolecular analysis system for use with J 1500 CD Spectrometer by Jasco
- Automated measurement of up to 192 samples (two 96-well plates)
- Enables automated scanning measurements with pre-programmed parameters
- For use in in pharmaceutical, process and biotechnology and food chemistry labs
- Delivers open-access unattended measurement, analysis and reporting
- Included software delivers reproducible and automated measurements and reliable structural analysis; with dust cover
- Autosampler maintains microplate rack at a constant temperature
- Eliminates human error and bias in measurement acquisition and biomolecular characterization
- Ideal for thermal stability studies with separate cell and well-plate temperature control
- Batch data processing calculates melting temperature secondary structure analysis and comparability analysis
- Dry-up function, 3 (Max: 200, 100, 100ml) cleaning solution
- Unit components:
- Sampling needle pierces plater without risk of debris
- Temperature controlled microplate rack for two 96-micro well plates and three solvent washing system
- Air pump completely ejects flow cell and tubing samples as well as dries flow path after a washing cycle
- Advanced Features: Spectrum Test Measurement, Open Access Function, Air Volume Auto Optimization, Automatic Calculation of Optical Constants, Batch Processing, Simultaneous Measurement Function
- Conventional and high-throughput measurement modes
- Adjustable wash cycle: three solvent washes
- Air drying system eliminates sample dilution
- Included measurement and analysis programs:
- Spectra Measurement and Spectra Analysis
- Temperature/Wavelength Scan Measurement
- Variable Temperature Measurement
- Regulatory Compliance with Spectra Manager CFR
- Peltier temperature controlled flow cell specifications:
- 0.2 mm Flow Cell: 80~250 μL sample volume, 5 μL cell volume
- 0.5 mm Flow Cell: 80~250 μL sample volume, 13 μL cell volume
- 1 mm Flow Cell: 80~250 μL sample volume, 25 μL cell volume
- 2 mm Flow Cell: 150~250 μL sample volume, 100 μL cell volume
- Jasco HTCD Applications: small pathlength cell reproducibility; multiple protein samples of CD, absorbance and fluorescence measurements; stability evaluation of antibodies
- Options for powerful analysis with automated post measurement processing: Spectrum QC Test JWSQC-530, Multivariate SSE Analysis JWMVS-529, Thermal Denaturation Multi-Analysis JWTDA-519
Specs
• Spectrometer Type: Circular Dichroism
• Brand: J-1000 Series
• 21 CFR Part 11: Yes
• Manufacturer SKU: 7069-J194A
• Unit of Measure: EA