Product Details
- Maximum Temperature: 300°C
- Internal Dimensions W" x D" x H" (mm): 23.64 x 17.14 x 17.14 in. (601 x 435 x 435 mm)
- Standard Single door 4.1 cu. ft. model with Class M6 replaceable filter cartridge
- Includes 2 chrome-plated racks
- Temperature range: 10 °C above ambient temperature to [°C]: 300
- Interior volume: 4.1 cu.ft. (116 L)
- Wall clearance back [in]: 6.3 in. (160 mm)
- Wall clearance sidewise [in]: 3.94 in. (100 mm)
- Temperature variation at 150 °C [± K]: 2.5
- Temperature fluctuation [± K]: 0.8
- Heating-up time to 150 °C [min]: 20
- Recovery time after 30 seconds door open at 150 °C [min]: 12
- Air circulation (approx.) [x/min]: 20
- Volumetric flow rate of exhaust air according to EN 1539 at 50 °C [ca. L/min]: 400
- Highest permitted solvent quantity (at T-180 °C, M-100g/mol, U-40g/m3, K=0,5) [g]: 6.65
- Nominal power [kW]: 2.9
- Phase (Nominal voltage): 1~
- Energy consumption at 150 °C [Wh/h]: 1200
- Sound-pressure level [dB(A)]: 57
- Permitted load: 132 lbs. (59.9 kg)
- Load per rack: 66 lbs. (29.9 kg)
- Number of shelves (std./max.): 2/5
- Computer interface: RS 422
- Silicone and dust-free inner chamber and symmetric airflow
- Meets EN 1439 requirements and DIN EN 1539-2010-08 standard
- Includes 2 chrome-plated racks
- Silicone and dust-free inner chamber and symmetric airflow
- Easy-to-change fresh air filter cartridges (replaceable) ensures constant fresh air quality
- Symmetrical air flow with electronic monitoring system, automatic deactivation of heating
- APT.line™ preheating technology provides optimal temperature uniformity and faster recovery times
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Controller: time-segment and real-time programming
- 60-mm-thick insulation, keeping heat dissipation to a minimum
- List of Options and Accessories for FDL 114
- Access port with silicone plug
- Calibration certificate, expanded
- Calibration certificate, temperature
- Cart with casters and locking brakes
- Coil coating door flap
- Door gasket
- Door lock
- Measurement of air exchange rate
- pH-neutral detergent
- Rack
- Rubber pads
- Shelf (perforated, stainless steel
- Software (Version 2 to 3, GLP, Basic, Standard and GLP DEMO editions)
- Specimen temperature display
Specs
• Type: General Protocol
• Maximum Temperature: 300°C
• Material: Coated Steel
• Capacity: 4.1 cu. ft.
• Convection Type: Mechanical
• Controls: Digital
• Model: FDL Series
• Manufacturer SKU: 9010-0292
• Capacity Range: 4 to 8 cubic feet
• Unit of Measure: EA
• Marks & Listings: UL
• Electrical Specifications: 240 V, 50/60 Hz
• Dimensions, Product: 32.7"W x 27.3"D x 31.7"H
• Weight, Shipping: 168 lb
• Dimensions, Shipping: 32.727"W x 31.7"D
• Package Type: Palletized