Worldwide Pricing and Secure Global Shipping Available!
5102-30
Terra Part # 5102-30
$17,964*
*See discounts and promos in cart Web-exclusive discount applies only to quotes/orders placed directly on our website; not valid for phone, email, or other ordering methods.
Usually ships in 10-20 business days

Want it faster ? Read about FasTrak

Ships Free Free shipping in contiguous USA
Accessories related to Terra Part # 5102-30
62799
Lambda 365 UV/Vis Spectrophotometer with UV Lab Software
Product Details
  • Requires connection to PC for operation
  • Includes: UV Express Software #N4108000 auto aligns optional multi-cell changers
  • Dimensions: 19.5 x 19.7 x 10.6in (495 x 500 x 270 mm)
  • Electrical: 100‐240 V 50/60 Hz
  • Source Lamp: Tungsten/Deuterium
  • Monochromator Blazed holographic grating with 1200 gr/mm, Czerny‐ Turner with 0.2 m focal length
  • Detector: Si diodes, Sample and Reference
  • Photometric System: Double Beam Optics
  • Wavelength Range: 190‐1100 nm
  • Spectral Bandwidth: 0.5, , 1, 2, 5, 20 nm
  • Data Interval: 0.05, 0.1, 0.5, 1, 2 nm
  • Wavelength Accuracy: ±0.1 nm at D2 peak @ 656.1 nm, +/‐ 0.3 nm for full range
  • Wavelength Reproducibility: ±0.1 nm
  • Photometric Range: +/‐ 4 A
  • Photometric Accuracy: +/‐ 0.002A (0‐.5 Abs), +/‐ 0.004A (.5‐1 Abs)
  • Photometric Reproducibility: <0.001AU @ 0.5 and 1.0 AU, <0.002AU(60 mg/L Potassium Dichromate)
  • Stray Light: < 1.0% ( 198 nm KCL ); <0.02% (220 nm Nal); <0.02% (340 nm NaNO2 )
  • Photometric Noise: < 0.00005 Abs (at 700 nm, RMS )
  • Interface: USB
  • Compact and modular UV/Vis Spectrophotometer
  • Double beam optics for high stability and low stray light
  • Extremely high signal to noise ratio
  • Modular design and a large number of accessories provides for maximum usability
  • Large sample compartment fits more than 10 sampling accessory combinations
  • Ideal for use in biotechnology, environmental, genetics, manufacturing, pharmaceutical QA/QC and academic labs
  • Use in: applications requiring regulatory compliance, kinetic measurements, determination of nucleic acid concentration, determining the thickness and reflectance/transmission of films
  • Accessories sold separately: Transmission and Reflectance Holders, Variable and Fixed Angle Reflectance Accessories and Base Plates, Peltier Controlled Systems, Lambda 365 Software

Wavelength Range: 190-1100 nm

Samples per Run: 8 Samples

21 CFR Part 11: Yes

Spectral Resolution: 0.5 nm

Manufacturer SKU: N4100020

Type: Manual

Unit of Measure: EA

Electrical Specifications: 120/240 V, 1 Ph, 50/60 Hz

Weight, Product: 55 lb

Dimensions, Product: 19" W x 19" D x 10" H

Weight, Shipping: 75 lb

Dimensions, Shipping: 22" W x 22" D x 15" H

Package Type: Box

Buy Accessories
  1. Accommodates any standard 10 mm cells  |  5102-31 displayed
    Request Quote
    Increase Down Increase Up
  2. Measures transmittance of various sample types such as films, glass, plates and more  |  5102-32 displayed
    Request Quote
    Increase Down Increase Up
  3. Adjusts angle of solid samples for transmission measurements  |  5102-33 displayed
    Request Quote
    Increase Down Increase Up
  4. Used for film thickness measurements  |  5102-34 displayed
    Request Quote
    Increase Down Increase Up
  5. Varying length cuvette holder for Perkin Elmer’s Lambda 365 spectrophotometer  |  5102-35 displayed
    Request Quote
    Increase Down Increase Up
  6. Uses recirculating liquid to maintain temperature control over standard 10 mm cells  |  5102-36 displayed
    Request Quote
    Increase Down Increase Up
  7.  |  5102-37 displayed
    Request Quote
    Increase Down Increase Up
  8. Measures diffuse reflectance, total transmittance, diffuse transmittance and performs color analysis  |  5102-38 displayed
    Request Quote
    Increase Down Increase Up
  9. Used for connecting Dip Prove Fiber Optic with the system  |  5102-40 displayed
    Request Quote
    Increase Down Increase Up
  10. Accommodates any standard 10 mm cells; up to 8 samples  |  5102-41 displayed
    Request Quote
    Increase Down Increase Up
  11. Designed for test tubes, vials, ampules, cylinder type, cuvette, etc.  |  5102-44 displayed
    Request Quote
    Increase Down Increase Up
  12. Measures transmittance of various features of thin samples such as film, glass and plate  |  5102-45 displayed
    Request Quote
    Increase Down Increase Up
  13. Accurately positions small volume cuvettes  |  5102-50 displayed
    Request Quote
    Increase Down Increase Up
  14.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  15.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  16.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  17. Used for installing Variable Angle Reflectance Accessory  |  5102-47 displayed
    Request Quote
    Increase Down Increase Up
  18.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  19. Used for installing Fixed Angle Reflectance Accessory  |  5102-49 displayed
    Request Quote
    Increase Down Increase Up
  20. Peltier Controlled Single Cell, with Peltier Controller for LAMBDA 365
    Request Quote
    Increase Down Increase Up
  21. For thermal denaturation, kinetics and precise temperature control applications  |  5102-15 displayed
    Request Quote
    Increase Down Increase Up
  22. For thermal denaturation, kinetics and precise temperature control applications  |  5102-15 displayed
    Request Quote
    Increase Down Increase Up
  23. For thermal denaturation, kinetics and precise temperature control applications  |  5102-61 displayed
    Request Quote
    Increase Down Increase Up
  24. For thermal denaturation, kinetics and precise temperature control applications  |  5102-15 displayed
    Request Quote
    Increase Down Increase Up
  25.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  26. ColorMaster Viewer Software for LAMBDA 365 UV/Vis Spectrophotometer
    Request Quote
    Increase Down Increase Up
  27.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  28.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  29.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  30.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  31.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  32. Nano Stick-D, Z 15, Black
    Request Quote
    Increase Down Increase Up
  33. Nano Stick-D, Z 15, Blue
    Request Quote
    Increase Down Increase Up
  34. Nano Stick-D, Z 15, Red
    Request Quote
    Increase Down Increase Up
  35. Nano Stick-D, Z 15, Gold
    Request Quote
    Increase Down Increase Up
  36. Nano Stick-D, Z 15, Silver
    Request Quote
    Increase Down Increase Up
  37. ASX-260 Autosampler 110/220V 50/60 Hz
    Request Quote
    Increase Down Increase Up
  38. Automate sample analysis and automatically deliver samples to cuvette  |  5102-25 displayed
    Request Quote
    Increase Down Increase Up
  39. Auto Sipper Accessory
    Request Quote
    Increase Down Increase Up
  40. Used with auto sipper accessory (N4101012)  |  5102-39 displayed
    Request Quote
    Increase Down Increase Up
  41. Extended Product Warranty
    Request Quote
    Increase Down Increase Up
  42. Equipment Testing
    Request Quote
    Increase Down Increase Up

Features and Benefits

Applications and Specifications