Summary

  • High-speed biomolecular analysis system for use with J 1500 CD Spectrometer by Jasco
  • Automated measurement of up to 192 samples (two 96-well plates)
  • Enables automated scanning measurements with pre-programmed parameters
  • For use in in pharmaceutical, process and biotechnology and food chemistry labs
  • Delivers open-access unattended measurement, analysis and reporting
  • Included software delivers reproducible and automated measurements and reliable structural analysis; with dust cover
  • Autosampler maintains microplate rack at a constant temperature
  • Eliminates human error and bias in measurement acquisition and biomolecular characterization
  • Ideal for thermal stability studies with separate cell and well-plate temperature control
  • Batch data processing calculates melting temperature secondary structure analysis and comparability analysis
  • Dry-up function, 3 (Max: 200, 100, 100ml) cleaning solution
  • Unit components:
  • Sampling needle pierces plater without risk of debris
  • Temperature controlled microplate rack for two 96-micro well plates and three solvent washing system
  • Air pump completely ejects flow cell and tubing samples as well as dries flow path after a washing cycle
  • Advanced Features: Spectrum Test Measurement, Open Access Function, Air Volume Auto Optimization, Automatic Calculation of Optical Constants, Batch Processing, Simultaneous Measurement Function
  • Conventional and high-throughput measurement modes
  • Adjustable wash cycle:  three solvent washes
  • Air drying system eliminates sample dilution
  • Included measurement and analysis programs:
  • Spectra Measurement and Spectra Analysis
  • Temperature/Wavelength Scan Measurement
  • Variable Temperature Measurement
  • Regulatory Compliance with Spectra Manager CFR
  • Peltier temperature controlled flow cell specifications:
  • 0.2 mm Flow Cell: 80~250 μL sample volume, 5 μL cell volume
  • 0.5 mm Flow Cell: 80~250 μL sample volume, 13 μL cell volume
  • 1 mm Flow Cell: 80~250 μL sample volume, 25 μL cell volume
  • 2 mm Flow Cell: 150~250 μL sample volume, 100 μL cell volume
  • Jasco HTCD Applications: small pathlength cell reproducibility; multiple protein samples of CD, absorbance and fluorescence measurements; stability evaluation of antibodies
  • Options for powerful analysis with automated post measurement processing: Spectrum QC Test JWSQC-530, Multivariate SSE Analysis JWMVS-529, Thermal Denaturation Multi-Analysis JWTDA-519

Specifications

Spectrometer Type: Circular Dichroism

Brand: J-1000 Series

21 CFR Part 11: Yes

Manufacturer SKU: 7069-J194A

Unit of Measure: EA