- Energy efficient ULT Freezers ensure safe sample storage; suited for COVID-19 va ccine storage
- Available in 16.46 cu. ft. and 24.7 cu. ft. capacities
- Suitable for labs storing samples and materials at -86°C setpoint
- Long-term storage of biological, medical and chemical samples at ultra-low temperatures
- Environmentally-friendly refrigerants R-290 and R-170
Ultra-Low Freezers (-80°C)
6707-PP-13
6707-PP-13 77858
UF V Series Ultra-Low Temperature Upright Freezers by BINDER
Read more
Manufactured By: Binder
Warranty: Five-Year Manufacturer Warranty
Print
Want a quote quickly ?
Submit a QuickQuote requestSelect Product Options
Summary
- Energy efficient ULT Freezers ensure safe sample storage; suited for COVID-19 va ccine storage
- Available in 16.46 cu. ft. and 24.7 cu. ft. capacities
- Suitable for labs storing samples and materials at -86°C setpoint
- Long-term storage of biological, medical and chemical samples at ultra-low temperatures
- Environmentally-friendly refrigerants R-290 and R-170
- Interior with four compartments provide temperature stability during sample retrieval
- Freezer racks per compartment: 4 (16.48 cu. ft.); 6 (24.7 cu. ft.)
- Permitted load: 441 lbs.
- Includes: 3 stainless steel shelves and 12 shelf holders with screws, DIN plug, two spacers for rear wall distance and operating manual
- Maximum shelf capacity: 13 (all models)
- Range of temperature controller: -90 °C to -40 °C
- Setting range: -86 °C to 20 °C
- Lowest energy consumption in its class
- Material: rust-proof, stainless steel interior
- Zero-voltage alarm contact for in-house alarm system
- Cryobox (50 mm) capacity: 352 (16.46 cu. ft.); 528 (24.7 cu. ft.)
- Features: Powerful cascade compressor cooling unit, efficient thermal insulation with vacuum insulation panels, door gasket reduces ice buildup, ergonomic door handle, detachable stainless steel inner doors, operating hours counter, Ethernet interface, internal data logger, measure valued read via USB, 2 access ports, Ø 28 mm, rear
- Environment-specific data:
- Average heat dissipation at setpoint -80 °C and ambient temperature = 21 °C [W]: 330 (16.48 cu. ft.).; 340 (24.7 cu. ft.)
- Energy consumption at setpoint -80 °C and ambient temperature = 21 °C [kWh/d]: 7.9 (16.46 cu. ft.); 8.1 (24.7 cu. ft.)
- Sound-pressure level [dB(A)]: 47
- Performance data temperature:
- Cooling down time from 22 °C to -80 °C [min]: 360(16.48 cu. ft.); 450 (24.7 cu. ft.)
- Temperature fluctuation at -80 °C [± K]: 1.5
- Temperature variation at -80 °C [± K]: 2.5
- Warm-up time during power failure from -80 °C / -122 °F to -60 °C / -76 °F [min]: 230 (16.48 cu. ft.); 250 (24.7 cu. ft.)